TRACE32 LTS release

What is the TRACE32 LTS Release?

The TRACE32 LTS release is a special version of the TRACE32 software, intended for customers using discontinued products form Lauterbach.

Note
  • TRACE32 2020/09 LTS is based on the 2020/09 release and continues to support the discontinued products and features listed below.

  • Any products purchased after September 2020 are not guaranteed to be compatible with this LTS Release.

  • For compatibility inquiries regarding the LTS Release with more recent products, please contact our support team.

How to Get the TRACE32 LTS Release?

If you are using any of the discontinued products or features listed below, you can request a download link for the TRACE32 2020/09 LTS Release by submitting a support ticket.

Discontinued TRACE32 Products and Features supported by TRACE32 2020/09 LTS Release

Starting with Release 2021/02, the following older products and features have been discontinued. These products are not recommended for new projects.
However, if you need to use one of these products, the TRACE32 2020/09 LTS Release is the right choice for you:

TRACE32 In-Circuit Emulators:

  • ICE In-Circuit Emulators (all architectures)

  • FIRE In-Circuit Emulators (all architectures)

TRACE32 In-Circuit Debugging (ICD) Modules:

  • Debug Interface (LA-7700, LA-7701)

  • PODBUS Ethernet Controller (LA-7810..7814, LA-7820..7825)

  • Old PowerTrace module with 64 MByte trace memory (LA-7706)

TRACE32 ROM Monitors on EPROM Simulator (ESI) for:

  • XA51 (LA-7524)

  • 80C196 (LA-7516)

TRACE32 In-Circuit Debuggers (ICD) for:

  • 196EA (LA-7750)

  • MMDSP+ (LA-7836, LA-7625)

  • MC56000 and MC56100 (LA-7730)

  • 68HC12 (LA-7714) (Superseded by LA-3748)

  • MCS12 (LA-7717) (Superseded by LA-3748)

  • 68K (LA-7710) when running on old PowerDebug modules LA-7702 and LA-7704

  • 68HC16 (LA-7712) when running on old PowerDebug modules LA-7702 and LA-7704

Discontinued Virtual Target APIs:

  • TRACE32 Frontend for Virtio (VDI)

  • TRACE32 Frontend for VaST

  • TRACE32 Frontend for OseDB

Discontinued Operating System Support:

  • Windows Vista, XP and older

  • 32-bit Linux platforms

  • Qt4 Linux platforms (TRACE32 for Qt now requires Qt5)