[MPC5xxx] The external bus interface (EBI) fails when the debugger is connected

Authors list

The cause of this problem is that there are two signals which are multiplexed between debugger and EBI usage: EVTI and EVTO.


For the MPC5510 series, the function of these signals is controlled by the EVT_EN bit in the NPC_PCR register, which again is controlled by the debugger. The debugger will per default set the pin function to EVTI/EVTO. In order to use the signals for EBI (R/!W and !TA), use the EVTEN setting in the TrOnchip window:


TrOnchip.EVTEN ON ; signals have EVTI/EVTO function. EBI functions disabled (default)
TrOnchip.EVTEN OFF ; signals free for use by EBI or GPIO


IMPORTANT NOTES:

  • If the NEXUS adapter LA-7610 is used, EVTI must be physically disconnected from the debug/trace connector, because the LA-7610 will permanently drive EVTI.

  • If the NEXUS adapter LA-7630 is used, the EVTI pin will be tristated if TrOnchip.EVTEN is set to OFF. It is recommended to disconnect EVTI/EVTO from the debug connector anyway (see below).

  • If the signals are used for EBI, it is strongly recommended disconnecting EVTI/EVTO from the debug connector. Unterminated signals can cause EBI problems, especially if the debugger is not connected.